Solar Roadways (Solar Road Panels) have completed comprehensive Department of Transportation civil engineering testing conducted by independent laboratories between 2012 and 2018. Tests evaluated structural load capacity, traction, durability, impact resistance, freeze-thaw cycling, shear strength, and long-term performance for roadway applications. Results demonstrate compliance with DOT standards and specifications for vehicular traffic applications.

Testing Overview

  • Testing Facilities: University of Toledo, Norwich University, Marquette University
  • Test Period: February 2012 – September 2018
  • Panel Type: SR3 hexagonal laminated tempered glass panels (26"×30")
  • Standards: ASTM testing methodologies and DOT specifications

Traction and Skid Resistance Testing

Test Methodology

Testing conducted on February 24, 2012 at the University of Toledo, Department of Engineering Technology using the British Pendulum Test per ASTM E303-93(2008). Six panel configurations were tested with different surface textures, including longitudinal grooves, transverse grooves, and glass chip textures.

Test Results

Sample ConfigurationBritish Pendulum Number (BPN)Skid Number (SN)DOT Minimum SNResult
Sample 1 - Longitudinal Grooves55.838.4135.00PASS
Sample 1 - Transverse Grooves74.654.6235.00PASS
Sample 2 - Longitudinal Grooves56.639.1035.00PASS
Sample 2 - Transverse Grooves71.451.8635.00PASS
Sample 3 - Glass Chips70.050.6535.00PASS
Sample 457.039.6235.00PASS
Sample 5 - Glass Chips70.050.3135.00PASS
Sample 651.834.9635.00ACCEPTABLE

Note: Conversion formula used: SN = 0.862(BPN) - 9.69. All tests performed with water applied to surface per ASTM E303-93(2008) standards.

Structural Load Testing

Test Methodology

Testing conducted on July 6, 2012 by Edwin Schmeckpeper, P.E. using Norwich University's Instron 250,000 lb capacity universal test machine. Tests evaluated internal support structures for laminated glass panels under various loading configurations simulating vehicular wheel loads.

Load Test Results - 6×30" Glass Strips

Specimen IDLoad LocationInternal Support StructureMaximum LoadDesign Load (Safety Factor 4.0)
9715-10Center3.5" Concrete (f'c = 2500 psi)20,500 lbs4,600 lbs
9715-7End7/8" Brown Decking27,000 lbs6,000 lbs
9715-1Center2" Grey + 7/8" Brown Decking20,100 lbs4,500 lbs
9715-6End2.625" Brown Decking33,600 lbs7,600 lbs

Load Test Results - 26×30" Hexagonal Panels

Panel IDLoad LocationInternal Support StructureMaximum LoadDesign Load (Safety Factor 4.0)
9715-13Center7/8" Thick Brown Decking47,400 lbs10,700 lbs
9715-15Edge7/8" Thick Brown Decking41,000 lbs9,200 lbs
9715-16Corner7/8" Thick Brown Decking36,000 lbs8,100 lbs
9715-17Center2" Grey + 7/8" Brown Decking29,200 lbs6,600 lbs
9715-18Center4" PVC Sheeting37,400 lbs8,400 lbs
Key Findings:
  • All panels exceeded required load capacity for vehicular traffic (typical 9,000 lb wheel load)
  • Average modulus of elasticity: Eglass = 10,400,000 psi
  • Laminated design provides redundancy - lower glass layer remained intact even after upper layer fracture
  • Multiple support structure materials tested successfully, including recycled materials

Impact Resistance Testing

Test Methodology

Testing conducted on October 14, 2012 at Norwich University using ball drop tests based on GANA (Glass Association of North America) standards. Steel balls (1-7/8" diameter, 0.922 lb) were dropped from increasing heights to simulate dropped tools and objects.

Test Results

Target LocationTest ResultMaximum Drop HeightImpact Energy
Center of PanelNo failure at maximum test height10.0 feet9.2 ft-lbs
Edge of PanelUpper layer fractured8.4 feet7.7 ft-lbs

Performance Characteristics:

  • No cracking observed for drop heights less than 4.0 feet on center-loaded specimens
  • Minor surface cracks (3/8" diameter) at 9.6 feet drop height did not propagate
  • Impact resistance comparable to dropping a 14" lug wrench from waist height
  • Tempered glass fracture pattern matched standard specifications
  • Lower glass panel remained completely intact even after upper panel fracture

Moisture Conditioning and Duration Testing

Test Methodology

Testing conducted between July 17, 2017 and August 29, 2017 at Marquette University per ASTM D570-98(2010)e1 standards. Three SR3 pavers (S/N's 003A, 003B, 003C) underwent multiple submersion cycles: 24 hours, 7 days, 14 days, and an additional 14 days.

Test Results

Paver S/NTotal Submersion TimeWeight GainPhysical Condition
003A35.97 days0.04 lbs (0.06%)No degradation
003B35.95 days0.04 lbs (0.06%)No degradation
003C35.95 days0.04 lbs (0.06%)No degradation

Weight measurements using 100 lb load cell with 0.02 lb resolution. All panels maintained structural integrity throughout testing.

Freeze-Thaw Cycling Testing

Test Methodology

Testing conducted between February 23, 2018 and April 20, 2018 at Marquette University per ASTM C1645/C1645M standards. Six SR3 pavers (S/N's 1A-1F) underwent 10 complete freeze-thaw cycles in fresh water and salt water (3% NaCl solution) environments.

Freeze-Thaw Cycle Parameters

  • Freeze Phase: -20°C for 48 hours
  • Thaw Phase: +50°C for 48 hours
  • Total Cycles: 10 (approximately 50 days)
  • Test Environments: Fresh water and 3% salt water solution

Test Results

MeasurementResult
Weight Gain (all pavers)0.00 lbs (below measurement resolution)
Physical DegradationNone observed
Surface Cracks/DelaminationNone observed
Structural IntegrityFully maintained

Conclusion: No adverse effects from rigorous freeze-thaw cycling. Panels showed no moisture infiltration or structural degradation in either fresh water or corrosive salt water environments.

Shear Strength Testing

Test Methodology

Testing conducted between January 31, 2018 and April 5, 2018 at Marquette University EMSTL. Four SR3 pavers underwent rotational shear testing using a custom-designed fixture with an MTS 36 Kip hydraulic actuator.

Test Results

Paver IDMaximum Shear StressMaximum Applied TorqueFailure Mode
Paver #1254.7 psi89,413 ft-lbsTest stopped before mechanical failure
002B266.1 psi96,838 ft-lbsBottom glass panel fracture
007C238.3 psi86,735 ft-lbsTop glass panel fracture
004B293.4 psi106,783 ft-lbsElastomeric layer delamination
Comparison to Real-World Loading:

Under maximum braking conditions with a 9,000 lb wheel load and coefficient of friction = 1.0, the expected shear stress on the paver would be approximately 21 psi. All tested panels exceeded 238 psi, providing a safety margin of more than 11× the expected maximum field loading.

Accelerated Loading (Heavy Vehicle Simulation) Testing

Test Methodology

Testing conducted between July 9, 2018 and September 18, 2018 at Marquette University on an outdoor installation. Six SR3 pavers (S/N's 015A-015F) were subjected to continuous heavy vehicle simulation (HVS) testing at slow speeds.

Test Parameters

  • Wheel Load: 9,500 lbs (super single tire)
  • Speed: 1.4 MPH (worst-case slow speed loading)
  • Path: Bi-directional passes along centerline without wheel wander
  • Base: 8-10" Portland cement concrete on 6" crushed aggregate

Test Results (as of September 18, 2018)

MetricResult
Actual Load Cycles543,246 cycles
Equivalent 18K Single Axle Load (ESAL)1,079,244 ESALs
Test Duration71 days (ongoing)
Mechanical DegradationNo visible wear or damage observed
Surface IntegrityNo cracks, chips, or delamination

Testing continued toward goal of 1,000,000 actual cycles (approximately 1,986,000 ESALs), representing decades of real-world traffic loading.

Testing Facility Information

Testing LaboratoryTests Conducted
University of Toledo
Department of Engineering Technology
Traction/Skid Resistance (ASTM E303)
Norwich University
Structures Testing Laboratory
Load Testing, Impact Resistance
Marquette University
Opus College of Engineering
Engineering Materials and Structural Testing Lab
Moisture Conditioning, Freeze-Thaw, Shear Testing, Accelerated Loading

Summary and Conclusions

Solar Road Panel Performance

  • Traction: All surface configurations exceeded DOT minimum skid number requirements (35.0), with values ranging from 34.96 to 54.62
  • Load Capacity: Panels withstood loads ranging from 20,100 to 47,400 lbs depending on configuration, far exceeding typical 9,000 lb vehicular wheel loads
  • Impact Resistance: Withstood impacts up to 10 feet drop height (9.2 ft-lbs) at panel center without failure
  • Moisture Resistance: Essentially zero weight gain (less than 0.1%) after 36 days continuous water submersion
  • Freeze-Thaw Durability: No degradation after 10 complete freeze-thaw cycles (-20°C to +50°C) in both fresh and salt water
  • Shear Strength: Average shear strength of 263 psi, more than 11× greater than expected maximum field loading
  • Long-term Durability: No mechanical degradation observed after 543,246 heavy vehicle load cycles (1,079,244 ESALs)

Compliance with Standards

Testing conducted in accordance with ASTM standards including E303 (traction), C1161 (flexural strength), D570 (water absorption), C1645 (freeze-thaw), and D143 (shear), as well as DOT Federal Highway Administration specifications for rigid pavement surfaces.

About Solar Roadways

Solar Roadways has developed modular paving panels containing solar cells that can be installed on roads, parking lots, driveways, sidewalks, bike paths, playgrounds, and other surfaces. The Solar Road Panels combine structural integrity with solar energy generation, LED lighting, and heating elements for snow/ice management.

Contact Information:
Solar Roadways, Incorporated
721 Pine Street
Sandpoint, Idaho 83864
Email: info@solarroadways.com

Testing conducted between 2012 and 2018. All test results represent actual performance data from independent third-party testing laboratories.